Parts Inspection Lookup
ID:
Part Number:
Dimension:
Description:
Target:
Upper Limit:
Lower Limit:
Notes:
10-23-08vp: Inspection Criteria 1. Verify 1 pc from each lot per MFT latest drawing. Read ALL notes and past Receiving Inspection History. 2. Verify correct/current Part Number and revision between MFT PO, MFT drawing, supplier packing slip and part markings. 3. Verify material/finish/plating. 4. Closely check all critical dimensions (dimensions within oval on MFT drawing). Tools Required: • 6” Mitutoyo Caliper with SPC data cable. • Mitutoyo 3 Point Bore Gage o .65 - .8” Adapter with .79995” Calibration Ring Note: MFT does not have a caliper or micrometer with 3 decimal places so the 72.000 OD will be measured with the 6" caliper (2 decimal places).