Parts Inspection Lookup
ID:
Part Number:
Dimension:
Description:
Target:
Upper Limit:
Lower Limit:
Notes:
9/10/18vp: Use flange to assure it doesn't cover the 4mm hole. This was an issue on the previous batch from July 2017. 3-18-08vp *Use 12604 End Piece Shaft for fit verification of dia 16.000 hole with flat. It should not be loose or very tight. PO 10530, Qty 300 received without 4mm hole. NOTE: Tom P making fixture for drilling the 4mm hole for repeatable hole location by Darter. Once fixture is approved by MFT Engineering, Darter will use this fixture for drilling this hole. 9-10-18vp: Measured 16.075mm hole with BORE gage & .5-.65" adapter.